Megger testing procedure for motors pdf files

Ieee standards documents are developed within the ieee societies and the. How does one interpret the results of the megger test. To test a cable with a megger, you connect one probe to the outside of the cable and, with the power turned off, you touch the probe to the conducting wire at the point of connection. Timeresistance testing method this method is fairly independent of temperature and often. The universal testing standard for rotational equipment, ieee 432000, increased the test voltage recommendation to 10 kv for equipment rated 12 kv and above. These conditions result in a decrease in the surfacetosurface contact area with an associated increase in surfacetosurface contact resistance, ultimately causing excessive heating at the junction. Most electrical associations recommend this procedure. Insulation testing technical guides megger insulation. It is commonly used in the industry for acceptance testing prior to energizing the cable and for maintenance testing programs. A megger is used to verify the integrity of the insulation for safety reasons. A guide to diagnostic insulation testing above 1 kv.

Insulation resistance testing of low voltage cables in the. Megger test equipment products on sale at tequipment. Ieee std 1122004, ieee standard test procedure for polyphase. With one touch oltc from the ttru3, anyone can configure and test all. Motor electrical insulation testing travelers insurance.

Ieee std 432000 recommends a procedure for measuring insulation resistance of armature and field windings in. Megger testing procedures ieee electrical code issues. Operation general testing procedure can be altered to achieve optimum conditions for the it is advisable that the battery of the d e t 2 2 is fully test. It is both smaller and lighter than its predecessor, making it even easier to carry and store.

The complete guide to electrical insulation testing. Megger, norristown, pa 19403 of any shortage of materials. Hi, ive been asked to find an ieee or equivalent test procedure for meggering from the tleads in an mcc cubicle to the motor in the field. Connect the megger ground lead to the same ground plane the motor is connected to. Step 3 crank the handle for about a minute, and notice the resistance reading. Isbn 07389785 ss95211 no part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.

To megger test a dc motor, you might need more than a simple ohmmeter because the problem you are investigating may not become clear until the motor is in operation. Mn434 11 section 1 general information overview this manual contains general procedures that apply to baldor motor products. The leads used for connecting megger testing with the circuit should be fault free and the two connecting leads should have electrical continuity. For your protection, do not install, operate or attempt to perform. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of assets and cable networks at high, medium and low voltage.

Compliance check testing for the regulation of minimum energy performance standards meps is almost always performed on brand new off the shelf motors. Im not sure if this holds true with modern test equipment, but i think this should be taken into consideration when guarding equipment that could be damaged by a high test voltage, such as a low voltage transformer winding. Megger guide to electrical insulation testing pdf instrumart. Offering cat iv, the mit525 is compact, light 5 kv insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. The insulation resistance tester, generally known by its trade name megger, is capable of providing critical information regarding the condition of motor insulation. When it comes to checking out electric motors, there are special measuring instruments that may be used to detect and diagnose malfunctions. It can give an accurate reading of the measure of resistance and continuity available in a highvoltage circuit and electrical motor. This is important, because the highvoltage current in threephase. The megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. Set the voltage setting of the insulation resistance tester to 500v. Due to heat, vibration, and limited space, the insulation on motor windings is the weak link. Bm12, mj10 mutlivoltage analogue insulation and continuity.

Completing turns ratio tests on all transformer taps can be a cumbersome process. Condition monitoring visual oil analysismegger test marflex. Megger safety precautions when you use a megger, you could be injured or damage equipment you are working on if the following minimum safety precautions are not observed. Start the test by pushing the test button and wait until resistance values are stable. Understanding insulation resistance testing pdf 0712 technical assistance 800 34391.

It is checked by touching the free ends of the leads together while the megger button is pressed on to check for zero. Ieee std 1122004 revision of ieee std 1121996 ieee standard test procedure for polyphase induction motors and generators sponsor electric. How to use a megger to measure and test motor insulation. Megger testing procedures megger testing procedures. A megger is an ohmmeter that measures resistance in the megohm scale. Direct current highvoltage testing, which measures the current flow through the insulation at 5000 volts and above.

Delivered in onsite case with 1 operating manual, 2 elbowedstraight pvc leads 1. For a three phase motor, insulation resistance is usually measured between each motor winding or phase and between each motor phase and motor frame earth using an insulation tester or megger. The preferred location for megger testing is at the motor terminals in the marflex electrical cabinets. Connect this spike to the instrument terminal c2 h. I cover the different test methods, an analogy on how insulation testing works, safety and the use of insulation test equipment. Insulation resistance testing guide chauvin arnoux. Pdf in part 1 have been presented some tests as insulation resistance. Be sure to read and understand the safety notice statements in this manual. In addition to their famous insulation testers, they offer 30 distinct product groups with over 1,000 specific products. In this video you will find out how to test 3phase induction motor. Insert the current test spike into the ground 30 to 50 metres away from the earth electrode to to be tested. Mit525 5 kv diagnostic insulation resistance tester megger.

Electrical test equipment power station to plug megger. Threephase power, introduced by inventor nikoa tesla, uses a polyphase system of alternating current to supply power to large motors and motor control systems. The megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. Electricians motor and generator testing equipment megger. A guide to diagnostic insulation testing above 1 kv 5.

Megger considers this an excellent safety practice. Place one megger probe to the any mounting bolt on the breaker box to test for grounding continuity, then touch the other probe to a motor terminal. This document will focus only on the tests that are of importance for field installers which are described as installation and maintenance tests. Megger strongly recommends the general safety practices contained in ieee std. A megger is able to measure highvoltage resistance values. If a fraction of current flows, it can be measured by these highly sensitive meters. From power station to plug, megger test equipment helps you maintain the electrical network, monitor its condition and maintain supply to your customers.

The test measures the insulation resistance between the phases andor between phase and ground. Pd testing on switchgear aisgisgil water leak detection and monitoring. How to megger a motor also known as an insulation test. One of the sctm working conditions is related to motor. Meggers motor and generator testers ensure the correct phase connection in one of our easytouse testers. Except for ceramics and glass, all insulation materials suffer deterioration over time from normal heat of operation. These products provide testing solutions in critical maintenance areas including cable fault locating, protective.

Using the megger to test a threephase motor is rather easy, though the safety hazards for this procedure are quite high. This is due to easy access and megger test results. Iec 6003421 is a welcome development and it is hoped that this guidance document can. Be sure to follow good safety measures to prevent electrical shock. The first neta acceptance testing specifications for electrical power equipment and systems was produced in 1972. Standard for acceptance testing specifications for. A senior tech once told me the megger guard terminal is the same potential as the negative terminal. How to test a threephase motor with a megger hunker. This is an insulation test of motor windings, commonly referred to as megging, to megger, or to meg a motor. If the result shows that the resistance is under 1 on the meter, after the first 60 seconds, it likely means that the cable has an issue and needs to be removed. Whether it involves the connection cables, the sectioning and protection equipment, or the motors and generators, the electrical conductors are insulated using materials with high electrical. Connect the megger hot lead to a motor winding lead. Do not, however, use this standard to reduce any of the precautions given in this.

Megger has been working hard to make the best electrical test and measurement products for over 100 years. Insulation resistance testing is a nondestructive test procedure. Press the remote control button to store the result for the tap step. Megger invented insulation testing before the beginning of the 20th century and has continued to lead the market in. Note that the megger can check for faults to the motor iron, but not short. If any damage is found, file a claim with the carrier at once and notify megger or its nearest representative giving a detailed description of the damages observed. We are testing the motors insulation, more specifically between the motor windings and the motor casing. Highvoltage dc testing versus medium voltage testing there are two common methods of testing insulation on highvoltage equipment.

The motor and phase rotation tester permits the electrical contractor or industrial maintenance electrician to permanently connect and tape the terminals of the motor being installed, without having to first energize the motor by a temporary hookup from a power source, if. Testing methods based on the influence of the test. Threephase dualvoltage motors are used for most daytoday operations in todays industrial plants. The remote control function allows for oltc testing. The megger insulation tester is essentially a highrange resistance meter ohmmeter with a builtin directcurrent generator. The instrument should be examined for damage received in transit. Rpm insulation systems evaluation and maintenance guidelines. It uses less conductor material for power transmission than other methods while also providing a constant stream of power. The following is a summary of insulation resistance ir testing commonly referred to as megger testing of low voltage cables rated less than 5 kv, recognized by nexans. What is the procedure for testing insulation resistance in. Megger testing of instrument cables electric motors. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store. Offering cat iv, the mit1025 is compact, light 10 kv insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Megger test procedure manufactured goods electromagnetism.

Use meggers on highresistance measurements only such as insulation measurements. These motors run conveyor belts, pumps, fans, and many other applications. Well learn how to identify windings, check windings resistance and insulation resistance. Upon completion of this project, the neta technical committee began work on a maintenance document, and maintenance testing specifications for electrical power equipment and systems was published in 1975. Threephase dualvoltage motor insulation resistance testing. Ieee std 1122004, ieee standard test procedure for. Weve assembled helpful technical guides on insulation testing from leading manufacturers in the field. A viable solution is to megger test with highvoltage test equipment using 1,000 10,000. Five models are available for general purpose testing which. Electrical motors cable splices bus bar joints welding joints etc. Motors are susceptible to the gradual failure of their insulation resistance. Full compliance with this standard can be attained with just one tester, the mit10202.

520 521 575 1187 816 610 526 1467 485 1453 996 919 1070 231 54 639 820 228 414 861 202 674 1444 688 1143 610 232 915 475 1029 882 170 452 966 766 749 1122 424 246 121 612